Isocyanate Cure Conversion

NCO conversion from DSC, FTIR or glass transition, with cure kinetics, time to target and the network it builds

One number, measured four ways

A polyurethane cure has one quantity worth tracking: how much of the isocyanate has reacted. Call it α. Everything a formulator cares about – whether the part can be demoulded, whether the modulus has stopped climbing, whether free isocyanate remains – is a question about α or about the network it has built so far. The awkwardness is that no instrument measures it directly. Each technique measures something else and infers α from a calibration:

αDSC = 1 − ΔH / ΔH0   |   αFTIR = 1 − (ANCO/Aref)t ÷ (ANCO/Aref)0
(Tg − Tg0) ÷ (Tg∞ − Tg0) = λα ÷ (1 − (1 − λ)α)

Three routes to one number is not redundancy, it is the test. They rest on different physics and fail differently, so when they agree the number is probably right, and when they diverge the pattern of divergence says which one to distrust. That is what this page is for: enter what the instruments reported, and see all three side by side along with what the stoichiometry says is even possible.

Stoichiometry sets the ceiling

Before any measurement means anything, the formulation decides how far α can go. Isocyanate conversion is capped by whatever it has to react with. Run the isocyanate in excess and the hydroxyl runs out first, which caps α at 1/r where r is the ratio of isocyanate to hydroxyl equivalents. At index 105 that ceiling is 0.952, so a specification demanding 95 % NCO conversion is asking the formulation to go essentially to its limit, and a specification demanding 98 % is asking for something arithmetically impossible. That is worth checking before anyone blames the oven.

Water belongs in that arithmetic, and it counts twice. Water consumes one isocyanate to give a carbamic acid, which loses CO2 to leave an amine, and that amine consumes a second isocyanate to give a urea. So each mole of water removes two equivalents of NCO, and it does it while generating gas. A polyol at 200 ppm water is not dry: in the example below those 200 ppm shift the effective index by more than two points, which is larger than most people's weighing error. This page adds 2 × mol H2O to the hydroxyl equivalents before computing anything.

r = eqNCO ÷ (eqOH + 2 × mol H2O)   |   index = 100r   |   αmax = min(1, 1/r)

The gel point follows from the same equivalents. For a mixture of functionalities it is αgel = 1/√(r (fw−1)(gw−1)), with the functionalities averaged over groups rather than molecules, because a triol offers three chances to enter the network and a diol two. Water enters this as a difunctional hydroxyl component, which is one more reason wet polyol changes the answer.

The formulation

Components

Only used to turn moles of elastic strand into a concentration.

The conversion the cure has to reach to pass.

Calibration and measurements

Each route needs its own two-point calibration: the value at zero conversion and, for the Tg route, the value at full cure. Run an uncured specimen and a fully cured one and these come straight off those two traces.

Calibration

Roughly ΔCp∞/ΔCp0. Fit it if you have a Tg at a conversion you trust.

What the instruments reported

Kinetics and time to target

Urethane formation is second order, one isocyanate and one hydroxyl per bond. Integrating that for an arbitrary ratio gives a straight line through the origin:

ln[(1 − rα) ÷ (1 − α)] = kapp(1 − r)t    which at r = 1 becomes    α ÷ (1 − α) = kappt

kapp is k[OH]0 lumped together so it comes out per hour, which is the form worth quoting because it is what sets the cure schedule. Fitting several temperatures gives the activation energy from ln k = ln A − Ea/RT, and with Ea in hand the cure time at any other temperature follows.

The network at that conversion

Conversion on its own does not tell you whether a part is usable; the network does. Past the gel point, the same equivalents and functionalities that gave αgel also give the concentration of elastically effective strands by the Miller–Macosko recursive method, counting a junction only when at least three of its arms reach the infinite network. Two attached arms makes a chain extender and fewer makes a dangling end, and neither carries stress. The rubbery modulus follows as E′ = 3νeRT.

Where each method goes wrong

A worked example

The values loaded above are a polyether triol of 1000 g/eq at 200 ppm water, cured with a difunctional isocyanate of 125 g/eq. Those 200 ppm are 1.11 × 10−4 mol of water against 0.01000 eq of hydroxyl, and because each mole takes two isocyanates they add 2.22 × 10−4 to the effective hydroxyl equivalents – enough to move the index from 100.0 down to 97.8. The gel point lands at α = 0.719 and, because the isocyanate is now the deficient group, αmax is 1.

The DSC, FTIR and Tg columns agree to within a few parts per thousand, which is what synthetic data looks like and what real data does not; see the spread column for what your own numbers do. The rate constant comes out near 0.30 h−1 at 60 °C and 0.54 h−1 at 70 °C, for an activation energy of about 56 kJ/mol, which is the usual range for a tin-catalysed urethane. Those two together say the cure reaches 95 % in about 53 hours at 60 °C and about 29 hours at 70 °C – the familiar result that ten degrees roughly halves a cure.

Now change the isocyanate mass from 1.250 to 1.342 g, leaving every measurement exactly as it was. The index goes to 105.0 and αmax falls to 0.9521, so the 0.95 target now sits a thousandth below the ceiling. More tellingly, the fit degrades: R2 at 60 °C drops from 1.0000 to 0.9154, and the activation energy falls from 55.9 to 42.8 kJ/mol. Nothing about the measurements changed – only the stoichiometry they are being interpreted against.

That degradation is the useful part. The second-order form only straightens out when r is right, so a cure plot that curves is often telling you the index is not what you think it is, and a wet polyol or a mis-weighed isocyanate is a likelier explanation than exotic kinetics. Check the stoichiometry before blaming the oven.